Scanning, file and annotation attributes: Scan Attributes: Cover various aspects related to the performance and accuracy of Whole Slide Imaging (WSI) systems and scanners.

Attribute CodeAttribute NameDescriptionData typeAllowed valuesConstraintsCardinality
MIABIS-DIGITALPATHOLOGYSCAN-01Scan IdentifierA unique identifier of the scanStringAn ID as a free-text stringnone0:1
MIABIS-DIGITALPATHOLOGYSCAN-02Acquisition DateThe date and time of capturing an image or scanning a glass slideDateDATETIME values in ' YYYY-MM-DD hh:mm:ss ' formatDatetime format must be according to ISO 8601.0:1
MIABIS-DIGITALPATHOLOGYSCAN-03Imaging ProtocolThe performed protocol for capturing a digital imageEnumerated valueswhole Slide Imaging, slide Microscopy, WSI40XRGB, WSI20XRGB, gross Specimen Imaging, peri-operative Photographic Imaging, other (the value is known but cannot be classified into any of the predefined categories) NULL (the value is unknown)none1:1
MIABIS-DIGITALPATHOLOGYSCAN-04Container ConditionCondition of the scanned glass slide and coverslipEnumerated valuesGood, Acceptable, Unacceptable, Subject To Interpretation (The data provider is uncertain whether the container condition is acceptable or unacceptable)none0:1
MIABIS-DIGITALPATHOLOGYSCAN-05DeviceThe vendor-stated name of the equipment or scanner. The attribute should include both the vendor's name and the vendor-stated name of the device.Stringnone1:1
MIABIS-DIGITALPATHOLOGYSCAN-06Device Software VersionSoftware and firmware versions of the device usedStringnone0:1
MIABIS-DIGITALPATHOLOGYSCAN-07Scanning Operation ModeThe scanning procedure used to digitize a glass slide. This attribute does not describe the capabilities of the scanner used for digitization.Enumerated valuesAutomatic (digitization without any interference from the personnel responsible), Semi-automatic (digitization with minimal interference from the personnel responsible), Manual (the personnel responsible adjust several parameters during the digitization procedure)none0:1
MIABIS-DIGITALPATHOLOGYSCAN-08Z-StackingMethod of the Z-Stacking, also known as Focus StackingEnumerated valuessingle (one image layer generated by one focal plane in scanning), multiple (n image layers generated by n focal planes in scanning), extended (one image layer generated by the combination of n focal planes in scanning)none0:1
MIABIS-DIGITALPATHOLOGYSCAN-09Number of Focal PlanesNumber of focal planes along the vertical z-axis used for multiple and extended z-stacking methodsIntegernone0:1
MIABIS-DIGITALPATHOLOGYSCAN-10Distance between Focal PlanesDistance between acquisition focal planes given in micrometers (µm)Decimalnone0:1
MIABIS-DIGITALPATHOLOGYSCAN-11Tissue Scan AreaScanned tissue area given in mm²Decimalnone0:1
MIABIS-DIGITALPATHOLOGYSCAN-12Objective Lens MagnificationThe objective lens magnification used for the acquisition of whole slide images. This refers only to the lens magnification and not the final stored image encoded by the spatial resolution attribute.Enumerated values5X, 10x, 20x, 40x, other, NULLnone1:1
MIABIS-DIGITALPATHOLOGYSCAN-13Spatial ResolutionDimensions of a pixel in an image, measured in µmDecimalnone1:1
MIABIS-DIGITALPATHOLOGYSCAN-14Illumination MethodIllumination method used for the acquisition of whole slide imagesEnumerated valuesTransmission Illumination, Reflection Illumination, Epifluorescence Illumination, Brightfield Illumination, Darkfield Illumination, Oblique Illumination, Phase Contrast Illumination, Differential Interference Contrast, Total Internal Reflection Fluorescencenone0:1
MIABIS-DIGITALPATHOLOGYSCAN-15Illumination WaveLengthNominal wavelength of the illuminator in nmDecimalnone0:1
MIABIS-DIGITALPATHOLOGYSCAN-16Out-of-Focus Error RatePercentage of a scanned area that is out of focusDecimalthe values should preferably be generated by a (validated) algorithm and encoded as a value between 0 and 10:1
MIABIS-DIGITALPATHOLOGYSCAN-17Stitching and other Artifact Error RatePercentage of a scanned area that is affected by stitching errors or other scanning artifactsDecimalthe values should preferably be generated by a (validated) algorithm and encoded as a value between 0 and 10:1